Czech sport aircraft PS-28 SportCruiser Operator's Manual Page 42

  • Download
  • Add to my manuals
  • Print
  • Page
    / 116
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 41
PS-POH-1-1-11 SECTION 3
EMERGENCY PROCEDURES
P
P
S
S
-
-
2
2
8
8
C
C
r
r
u
u
i
i
s
s
e
e
r
r
Date: 2011-09-01
3-8 EASA approved Rev. No.: -
3.13 Electrical fire in flight
1. MASTER BAT & GEN - OFF
2. Other switches - OFF
3. CABIN HEATER - PUSH OFF
4. Ventilation - open
5. Emergency landing - perform according to 3.9 as soon as possible
3.14 Emergency descent
1. Airspeed - max. permitted - V
NE
= 138 KIAS
- V
NO
= 108 KIAS
- V
A
= 88 KIAS
2. Engine RPM - do not overrun max. 5,800 rpm
3.15 Generator failure
GEN “OFF” (on EMS screen) highlighted red and blinking, bringing up the
alarm bar at the bottom of the EMS screen with message, triggering the
external EMS warning light and audio alert.
Voltmeter (on EMS screen) indicates voltage under 12.5 V.
Ammeter (on EMS screen) permanently indicates negative current.
1. MASTER BAT & GEN - ON
2. Engine RPM - increase above 3,000 rpm
If the generator failure indication persists:
3. MASTER GEN - OFF – ON
If the generator failure indication persists:
4. MASTER GEN - OFF
5. All unnecessary
electrical equipment - OFF
6. Voltmeter - monitor voltage of battery
7. Land as soon as possible at nearest suitable airport.
Page view 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 115 116

Comments to this Manuals

No comments